◆Digital testing lab
Test it as much as you like. We'll be over here.
Both impact tests run right here on this page, against our real measured data, as many times as you want. Compare our foam with whatever you use today, drop weights on it, change the density, change the drop. Nothing is metered and nothing is behind a form.
How this works
Free, and genuinely unlimited
There is no trial, no credit counter and no paywall part-way through. Run a hundred comparisons if that is what it takes to decide.
No account to use any of it
You do not have to tell us who you are to run a test. We would rather you got an answer than filled in a form.
An account only if you want to keep something
The one moment we ask is when you want to save a result, line several up against each other or send one to our team. That needs somewhere to put it, which is all the account is for.
Everything here is built on the same measured data as the rest of the site, and every figure carries a label saying how we got it — measured on our own rig, or an engineering estimate. The labels are there so you can decide how much weight to give each number.
◆Coupon test
Pick two. Drop both.
Coupon geometry per ASTM D1621 §6.1 — 101.6 × 101.6 × 25.4 mm, which also satisfies ASTM D3574 Test C. Impact data per ASTM D1596.
Super Foam
Super Foam · 100 kg/m³
Three densities, same coupon. Densities from the SDSU study.
Compare against
Viscoelastic Solid Polymer · 1300 kg/m³
Ten common protective and structural materials.
Now drop the weight on both.
Free. No sign-up needed. Same 0.723 kg weight, same 1 m drop, on each coupon.
Acceleration is written × g, a multiple of standard gravity (g = 9.81 m/s²). Masses are in kg.
Super Foam · SFC100
Comparison material · Sorbothane
Both curves together
EstimateDropped from the same height, SFC100 spreads the impact over 11.7 ms and passes 60 × g through to whatever sits behind it. Sorbothane spreads it over 7.5 ms and passes 95 × g.
Both coupons take the same drop, so both absorb the same impulse. What differs is how long each one takes to do it, and that is what decides how much force reaches the part behind the pad. Neither answer is better in the abstract — they suit different jobs.
Typically chosen for
SFC100
Lowest transmitted force of our three grades
Light protection where the thing behind the pad is delicate and the impact energy is modest.
Typically chosen for
Sorbothane
Excellent vibration damping
Machinery mounts and vibration isolation, where steady-state damping matters more than weight.
How to read these numbers
- Peak acceleration (× g)
- The highest force that reaches whatever sits behind the pad. Lower means a gentler hit for the protected part. Reported as a multiple of standard gravity, g = 9.81 m/s², so 60 × g is sixty times the acceleration of free fall. Written × g throughout so it is never read as grams.
- Impact energy absorbed (%)
- The share of the incoming kinetic energy the material takes out of a single impact, rather than returning it as rebound. Measured on a drop-weight rig. It answers a different question from energy absorbed per unit volume: this is how much of one hit disappears, that is how much a given thickness can take before it bottoms out.
- Pulse duration
- How long the impact lasts. A longer pulse spreads the same energy over more time, which is how peak force comes down.
- Energy absorbed
- How much impact energy the material takes out of the system per unit of volume. Higher means more work done by the pad.
- Height recovery
- How much of its original thickness the coupon gets back afterwards. High recovery means the pad is ready for the next impact; low recovery means it is a single-use part.
- Drop weight (kg)
- The mass released onto the coupon — 0.723 kg here, from 1 m. Masses are given in kilograms on these pages so that g never has to stand for grams.
The numbers, side by side
Estimate| Property | SFC100 | Sorbothane | Evidence |
|---|---|---|---|
| Peak acceleration (× g) | 60.4 | 95.0 | Mixed |
| Impact energy absorbed (%) | 58.0 | — | Measured, one side |
| Energy absorbed (kJ/m³) | — | 40.0 | Estimate, one side |
| Height recovery (%) | 98.0 | 95.0 | Mixed |
| Retention over 7 impacts (%) | — | 90.0 | Estimate, one side |
Where each material sits
EstimateEvery material here trades energy absorbed against force transmitted. Materials to the right take more energy out of the impact; materials lower down pass less force to the part behind them. Different applications want different corners of this chart.
Keep exploring
Super Foam comes in three densities, and each one trades peak force against energy absorbed differently. Run the same comparison against a lighter or denser grade and watch the pulse change shape.
Or send us your part and we will test the real geometry.
Or stop simulating and hit one yourself.
This is a standard ASTM D1621 coupon. We will ship you the real thing in the grade you picked, so you can run this test on your own rig against whatever you use today.
Order this couponPreliminary estimates for screening only. Not a specification, and not a qualification to any standard. Every result needs engineering validation before use in a safety-critical application. Static compression set and sustained-load behavior are deliberately left out: we do not yet have validated data for them.
◆Multiple impact test
Multiple impact test.
A 0.723 kg drop weight on an 18 mm cube of our foam, up to seven hits. Change the settings and run it again as often as you like.
Density
Sample densities from the SDSU drop-tower study.
Number of hits
Free. No sign-up needed.
Force on impact, every hit
EstimatePeak force, first hit
Peak force, last hit
Hit duration
Longer is gentler
Energy absorbed
Keep playing: try a thinner cube, the other density or more hits, and see what changes.
How these results are made
These are estimates based on peer-reviewed drop-tower tests of our foam, where a 0.723 kg weight hit the same sample up to seven times (San Diego State University research, published in Advanced Engineering Materials, 2022). Real parts depend on shape, mounting and the loads they face, so when you talk to our design team we run a full simulation of your own part.
Save and compare your tests
Create a free account to keep every test you run, compare them side by side and share them with our design team.
Your tests this visit
Tap one to load it again.
What do you want to find out?
The two main tests are on this page — jump straight to either. The rest sit alongside the use cases they belong to. All of it is listed by the question it answers, because that is usually how the question arrives.
★The one time we ask
Keeping your results.
Run as many tests as you like without telling us anything at all. If you want to keep one — to compare runs from different days, to put a set of results in front of your team, or to send them to our engineers with a question — that is the point where a free account becomes useful, because the results need somewhere to live.
- Keep every test you run, with its settings
- Line several runs up against each other
- Send a set of results to our design team with a question
Free, and only ever used for your own work. Your tests are yours.
When pixels are not enough
At some point you will want to hold it.
A simulation can show you the shape of a pulse. It cannot tell you what the material feels like under your thumb, and it cannot be put on your own rig. We do not keep a shelf of pre-cut samples to post out, because we do not make foam in sheets — every piece that leaves this building was cast for somebody. So when you want something physical, it starts a project with us, and what you pay for it is credited in full against whatever the project becomes.