@@SFDATA@@{
 "updated": "2026-10-12T21:29:03.312Z",
 "note": "Cleared Super Foam test data for the website quick-answer assistant. Edit in Entries → Test data.",
 "rows": [
  {
   "category": "Measured impact performance",
   "property": "Energy absorption",
   "measures": "Energy absorbed per unit volume under impact",
   "standard": "Internal impact testing",
   "value": "71.7 kJ/m³",
   "status": "Measured",
   "source": "Internal testing",
   "test_date": null
  },
  {
   "category": "Measured impact performance",
   "property": "Multi-impact load retention",
   "measures": "Load-bearing capacity lost after repeated impacts",
   "standard": "Internal impact testing",
   "value": "< 20% loss after 7 impacts",
   "status": "Measured",
   "source": "Internal testing",
   "test_date": null
  },
  {
   "category": "Measured impact performance",
   "property": "Volumetric recovery",
   "measures": "Volume recovered after a projectile strike",
   "standard": "Internal impact testing",
   "value": "98% after a 25 m/s projectile impact",
   "status": "Measured",
   "source": "Internal testing",
   "test_date": null
  },
  {
   "category": "Measured impact performance",
   "property": "Shape recovery",
   "measures": "Height recovered after impact",
   "standard": "Internal impact testing",
   "value": "Up to 99% within milliseconds",
   "status": "Measured",
   "source": "Internal testing",
   "test_date": null
  },
  {
   "category": "Measured impact performance",
   "property": "Weight and stiffness",
   "measures": "Mass and stiffness vs. comparison foam",
   "standard": "Internal comparison",
   "value": "12% lighter, 30% stiffer",
   "status": "Measured",
   "source": "Internal testing",
   "test_date": null
  },
  {
   "category": "Mechanical & impact",
   "property": "Compression force deflection (CFD)",
   "measures": "Firmness and load-bearing capacity",
   "standard": "ASTM D3574 (Test C) / ISO 3386",
   "value": "200–400 kPa",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Mechanical & impact",
   "property": "Compression set",
   "measures": "Thickness recovery after long-term static deformation",
   "standard": "ASTM D3574 (Test D) / ISO 1856",
   "value": "0.4–1% loss",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Mechanical & impact",
   "property": "Tensile strength & elongation",
   "measures": "Structural integrity and tear/stretch resistance",
   "standard": "ASTM D3574 (Test E) / ISO 1798",
   "value": "1,379–6,205 kPa / 250% (range across densities)",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Mechanical & impact",
   "property": "Impact energy absorption",
   "measures": "Behavior under high-speed component impact",
   "standard": "ISO 11343 / OEM drop tests",
   "value": "26.7 J / 50% G-force reduction",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "NVH dampening",
   "property": "Dynamic mechanical analysis",
   "measures": "Glass transition temperature (tan δ)",
   "standard": "ASTM D4065",
   "value": "Tg ≈ −40 °C",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Air quality, safety & environment",
   "property": "VOC & FOG emissions",
   "measures": "Volatile and condensable compounds released",
   "standard": "VDA 278 / SAE J1756",
   "value": "VOC ≤ 10 μg/g · FOG 0 μg/g",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Air quality, safety & environment",
   "property": "Odor",
   "measures": "Intensity of smell under heat",
   "standard": "VDA 270 / SAE J1351",
   "value": "Grade 2",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Air quality, safety & environment",
   "property": "Formaldehyde emissions",
   "measures": "Restricted aldehydes",
   "standard": "ISO 16000-3 / OEM specific",
   "value": "0 ppm",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Air quality, safety & environment",
   "property": "Horizontal burn rate",
   "measures": "Flame spread if ignited",
   "standard": "FMVSS 302 / ISO 3795 / SAE J369",
   "value": "Self-extinguishing",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Air quality, safety & environment",
   "property": "Humidity / hydrolysis",
   "measures": "Degradation in hot, humid climates",
   "standard": "ISO 2440 (tropical test)",
   "value": "< 2.5% property change",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Air quality, safety & environment",
   "property": "Accelerated weathering (UV)",
   "measures": "Color fading and surface degradation",
   "standard": "SAE J2527 / SAE J2412",
   "value": "ΔE < 3.0 / Grade 4.0",
   "status": "Estimate",
   "source": null,
   "test_date": null
  },
  {
   "category": "Formulation",
   "property": "PFAS",
   "measures": "Presence of PFAS (“forever chemicals”)",
   "standard": "Formulation",
   "value": "100% PFAS-free",
   "status": "Formulation",
   "source": null,
   "test_date": null
  },
  {
   "category": "Formulation",
   "property": "Blowing agent",
   "measures": "How cells are formed",
   "standard": "Formulation",
   "value": "100% water-blown, with no CFCs, HCFCs or auxiliary blowing agents",
   "status": "Formulation",
   "source": null,
   "test_date": null
  }
 ]
}@@END@@